CS Water Filter 125 Micron: Protection for Garden Irrigation
The CS Water Filter 125 Micron filters larger dirt particles from irrigation water before they reach connected hoses and other components. Its stainless steel filter mesh can therefore help reduce deposits and blockages in the irrigation system.
The practical backflushing function allows the filter to be cleaned as part of regular maintenance. The supplied connectors make it easier to integrate the filter into a suitably configured water supply.
- 125 micron filtration rating
- Stainless steel filter mesh
- Backflushing function
Mechanical Filtration of Dirt Particles
The mesh has a filtration rating of 125 microns (0.125 mm) and retains larger solid impurities. This helps protect downstream irrigation components.
Very fine particles may pass through the mesh. Dissolved substances such as water hardness minerals and dissolved iron are not removed by this type of mechanical filtration.
Cleaning by Backflushing
The integrated backflushing function allows accumulated dirt particles to be flushed out of the filter. This simplifies routine maintenance and can help prevent flow restrictions caused by contamination.
A quick hose connector and a tap connector are included for installation.
Important Selection Information
The required filtration rating depends on water quality and the needs of the connected irrigation system. Additional or finer filtration may be useful for more heavily contaminated water.
This water filter has no integrated pressure reducer. The permitted water pressure and required flow rate must therefore be matched to the connected components.
Product safety information
Manufacturer information:
CS Bewässerungssysteme GmbH
In der Aue 29
Hessen
Reichelsheim, Deutschland, 64385
info@cs-wss.com
www.cs-wss.com
Responsible person:
CS Bewässerungssysteme GmbH
In der Aue 29
Hessen
Reichelsheim, Deutschland, 64385
info@cs-wss.com
https://cs-wss.com/
| Item information |
Value |
| Shipping weight: |
0,22 kg
|
| Item weight: |
0,22 kg
|
Technical Specifications
| Product |
CS Water Filter 125 Micron |
| Filter Type |
Mechanical particle filter |
| Filtration Rating |
125 microns (0.125 mm) |
| Filter Element |
Stainless steel mesh |
| Housing Material |
Plastic |
| Cleaning |
Backflushing function |
| Integrated Pressure Reducer |
No |
| Maximum Inlet Pressure |
6 bar |
| Operating Temperature |
0 °C to +40 °C |
| Filter Connection |
3/4 inch male thread |
| Included Connectors |
Quick hose connector with 3/4 inch female thread and tap connector |
| Dimensions |
Approx. 23 cm height × 12 cm diameter |
| Water Flow Direction |
Indicated by an arrow on the filter housing |
| Application |
Suitable garden irrigation systems |
| Winter Storage |
Drain, remove and store in a frost-free location |
Note: The 6 bar pressure limit applies to the water filter. Connected hoses and other components may have lower permissible pressure ratings. A contaminated filter element can reduce water flow.
Application Instructions
Installation and Connection
The CS Water Filter 125 Micron is installed in the water supply line of a suitable irrigation system. It retains larger dirt particles and includes a backflushing function.
- Check the water filter for visible damage before installation.
- Choose an accessible installation point so the filter can be cleaned and removed before freezing conditions.
-
Observe the water flow direction: The arrow on the housing indicates the intended flow direction towards the irrigation system.
- Connect the supplied quick hose connector with 3/4 inch female thread and the tap connector to suitable mating connections.
- Slowly open the water supply and check all connections for leaks.
Water Supply and Operating Conditions
The water filter has a specified maximum inlet pressure of 6 bar. It does not contain an integrated pressure reducer and therefore does not regulate the outlet pressure to a defined value.
- Observe the operating limits of connected hoses, valves and other components.
- If the supply pressure exceeds the limits of downstream components, use suitable separate pressure regulation.
- Ensure sufficient water flow. The available flow depends on factors including supply pressure, connectors and the condition of the filter.
- With a low available water head, account for the filter's additional flow resistance and check the performance of the entire system.
Filtration and Water Quality
The stainless steel filter mesh rated at 125 microns (0.125 mm) retains larger solid impurities. This can help reduce deposits in downstream irrigation components.
- Use water that is as clean as possible and regularly check the filter for contamination.
- For more heavily contaminated water, consider suitable additional prefiltration or a finer filtration stage.
- Very fine particles may pass through the mesh. Dissolved substances such as water hardness minerals and dissolved iron are not removed by this type of mechanical filtration.
- Any additional filtration stage must be suitable for the available pressure and required flow rate.
Backflushing and Cleaning
The backflushing function allows accumulated dirt particles to be flushed out of the filter. Cleaning frequency depends on water quality and the level of contamination.
- Before maintenance, shut off the water supply and fully release the pressure.
- For backflushing, open the lower closure according to the intended operating procedure and close the normal outlet to prevent dirt from entering the irrigation system.
- Supply flushing water in a controlled manner and direct dirty water to a suitable drainage point.
- After flushing, shut off the supply again, securely refit the lower closure and reopen the normal water path.
- Check all connections for leaks and replace damaged filter elements or seals where necessary.
- Do not dismantle the filter housing while it is pressurised.
Winter Storage
The specified operating temperature range is 0 °C to +40 °C. Freezing residual water can damage the filter housing.
- Before freezing conditions, shut off the water supply and fully release the pressure.
- Remove the filter and drain it as completely as possible.
- Store the filter in a dry, frost-free location.
- Check the housing, filter element and seals before putting the filter back into operation.
There are no reviews yet.